Продукты

High Purity MTBE HPLC & Electronic Grades

    VTB
    Спецификации
    Код ТН ВЭД 508149
    Productname High Purity MTBE HPLC & Electronic Grades
    Grade HPLC & Electronic Grades
    Chemicalname Methyl tert-butyl ether
    Synonyms MTBE; tert-Butyl methyl ether; 2-Methoxy-2-methylpropane
    Casnumber 1634-04-4
    Ecnumber 216-653-1
    Molecularformula C5H12O
    Molecularweight 88.15 g/mol
    Appearance Clear colorless liquid
    Odor Ether-like
    Purity ≥99.9%
    Density 0.7405 g/cm³ at 20 °C
    Boilingpoint 55.2 °C
    Meltingpoint -109 °C
    Flashpoint -10 °C (closed cup)
    Autoignitiontemperature 374 °C
    Explosivelimits 1.5–8.5% (v/v) in air
    Refractiveindex 1.369 at 20 °C
    Viscosity 0.36 mPa·s at 20 °C
    Vaporpressure 27 kPa at 20 °C
    Watersolubility 42 g/L at 20 °C
    Logp 0.94
    Watercontent ≤0.03% (HPLC grade); ≤0.005% (electronic grade)
    Nonvolatilematter ≤5 ppm (HPLC grade); ≤1 ppm (electronic grade)
    Uvabsorbance ≤0.01 AU at 254 nm
    Metals ≤10 ppb (electronic grade)
    Particles ≤100 particles/mL >0.5 µm (electronic grade)

    Как аккредитованный завод высокой чистоты MTBE HPLC и электронных сортов, мы соблюдаем строгие протоколы качества - каждая партия подвергается строгим испытаниям для обеспечения последовательных стандартов эффективности и безопасности.

    Упаковка и хранение
    Упаковка
    Доставка
    Хранение
    Применение высокой чистоты MTBE HPLC и электронных сортов

    For normal-phase liquid chromatography of free fatty acids, monoglycerides, diglycerides, and polyethylene glycol derivatives on unmodified silica, methyl tert-butyl ether is employed as a polar-aprotic modifier rather than as a bulk mobile phase. The typical isocratic blend consists of n-hexane, methyl tert-butyl ether, and 2-propanol in volumetric ranges from 80:20:2 to 95:5:0.5, adjusted according to the column batch and the acid number of the sample extract. Mobile phase preparation is conducted in borosilicate reservoirs fitted with 0.1 µm polytetrafluoroethylene inlet filters, and the blend is degassed under vacuum followed by helium sparging at 15 mL/min to prevent detector drift when the UV absorbance is monitored at 210 nm. The solvent viscosity of approximately 0.35 mPa·s at 20°C is lower than that of isopropanol-containing mixtures, which reduces backpressure on a 250 mm × 4.6 mm silica column at 2.0 mm/s linear velocity to between 90 bar and 140 bar on standard binary pumps. Detector baseline stability over a 30-minute drift test is considered acceptable only if the photometric noise does not exceed 5 × 10−5 AU; this criterion is applied after the column has been equilibrated for 10 column volumes. High-purity MTBE for HPLC is specified with a GC assay of at least 99.9% by ASTM D5441, a water content not exceeding 0.02% by ASTM D1364, and a non-volatile residue below 5 mg/L by ASTM D1353. These limits are representative commercial certificate-of-analysis values and should be verified against the vendor lot before use because published data for this specific configuration are limited.

    Column wash cycles after use of high-purity MTBE in normal-phase methods are configured to avoid residual silanol-bound water from the sample extract. A gradient reverse wash with methyl tert-butyl ether at 1.0 mL/min for 20 minutes followed by n-hexane at 0.5 mL/min for 10 minutes is applied before the column is stored in n-hexane/MTBE 95:5 by volume to minimize peroxide accumulation in the eluent. Peroxide concentration in the stored column eluent is checked monthly with a test strip calibrated at 0.5 mg/kg, and columns that have been exposed to peroxide levels above 1.0 mg/kg are regenerated with an isopropanol wash to prevent irreversible binding of oxidation products to the silica surface. The use of MTBE as a sample diluent has a narrow operational window for analytes that are sensitive to trace peroxides; samples containing oxidation-labile compounds such as vitamin A palmitate or conjugated linoleic acid should be supplemented with 10 mg/L butylated hydroxytoluene or an equivalent radical scavenger only after the scavenger is shown to be chromatographically silent under the same gradient conditions. The low water tolerance of unmodified silica columns means that a solvent lot near the 0.02% water limit can require predrying with activated 3A molecular sieves or a silica-based solvent drying column before use in acid-sensitive separations. Fluoroelastomer seals and PEEK check valves are preferred because MTBE slowly extracts phthalate plasticizers from flexible polyvinyl chloride tubing, producing extraneous peaks at 220 nm and 254 nm that are absent from control injections. When MTBE is used as a sample diluent for non-aqueous reversed-phase methods, the injection volume should not exceed 10 µL per 100 µL loop because the high vapor pressure of 27.8 kPa at 20°C can cause needle-seat outgassing with autosamplers operating above 25°C ambient temperature.

    ParameterHPLC grade limitElectronic grade limitTest method
    Assay≥ 99.9%≥ 99.95%ASTM D5441
    Water≤ 0.02 wt%≤ 0.005 wt%ASTM D1364
    Non-volatile residue≤ 5 mg/L≤ 2 mg/LASTM D1353
    Total trace metals≤ 1 mg/L≤ 50 µg/LICP-MS after evaporation
    Peroxide as H₂O₂≤ 0.5 mg/kg≤ 0.2 mg/kgsupplier peroxide test

    Trace-Metal Budgets in Electronic-Grade MTBE for Quartz Oscillator Cleaning

    Electronic-grade MTBE is selected for quartz oscillator cleaning and carrier-solvent applications not because of bulk solvency but because the post-evaporation ionic burden is low enough to prevent frequency shifts after wire bonding. Supplier certificates of analysis for electronic-grade lots typically list sodium, potassium, iron, nickel, chromium, copper, and zinc at or below 10 µg/kg per analyte, and total non-volatile residue below 2 mg/L by ASTM D1353. The solvent is dispensed through 0.2 µm PTFE capsule filters in an ISO Class 5 cleanroom, and the final rinse is performed in a nitrogen atmosphere with a dew point below −40°C. Compatibility with stainless steel, quartz, borosilicate glass, and PTFE is documented, while extended contact with aluminum and unlined mild steel is avoided because trace water and atmospheric oxygen can generate corrosive ether hydroperoxides at the metal surface. Because MTBE is a peroxide-forming ether, electronic-grade material is packaged in amber glass under nitrogen and opened containers are assigned a 90-day retest interval; peroxide concentration is maintained below 0.2 mg/kg by periodic passage through activated alumina columns that are validated to release no aluminum fines above the particle specification. The evaporation rate in an open bath is governed by the vapor pressure of 27.8 kPa at 20°C, which requires local exhaust ventilation with a face velocity of at least 0.5 m/s and a flash point control based on the tag closed-cup value of −28°C. Particle counts in as-received electronic-grade MTBE are monitored by light obscuration with channels at 0.2 µm and 0.5 µm; a typical specification is no more than 25 particles/mL at 0.2 µm and no more than 5 particles/mL at 0.5 µm. For high-precision metal parts where ionic contamination above 10 µg/L is unacceptable after drying, the final rinse is conducted with two successive 5 mL aliquots of fresh solvent rather than a single 10 mL rinse; this step reduces the cation carryover by dilution and is specified in the cleaning protocol after plasma ashing of resist residues. Electronic-grade MTBE is not a universal electronic solvent; its use in wafer cleaning must be qualified against the specific photoresist or bonding material because the ether can extract low-molecular-weight oligomers and deposit them as organic haze on active surfaces. Published data for this specific configuration are limited, and each cleaning line is qualified by evaporating 500 mL of solvent and analyzing the residue pattern by ion chromatography and total organic carbon before release.

    Does Methyl-tert-butyl Ether Extraction Preserve Acidic Phospholipid Recovery Without Chlorinated Solvent Carryover?

    In high-throughput lipidomics, methyl tert-butyl ether has replaced chloroform in a two-phase extraction protocol because the organic phase floats above the aqueous-methanolic phase, allowing automated liquid handling without puncturing a lower chloroform layer. The published method uses 200 µL of biological fluid, 1.5 mL of methanol, 5 mL of high-purity MTBE, and 1.25 mL of ultrapure water, followed by shaking at 1,000 rpm for 10 minutes and centrifugation at 10,000 × g for 5 minutes at 4°C. Acidic phospholipids including phosphatidic acid and phosphatidylinositol are recovered primarily in the upper MTBE-rich layer; published recovery data for this specific configuration are limited, and individual laboratories validate recovery against internal deuterated standards in each 96-well batch. The requirement for high-purity MTBE in this workflow arises from the electrospray ionization source, where phthalate esters, fatty acid residues, or non-volatile plasticizers from technical-grade solvent produce background ions that suppress phosphatidylcholine detection below 100 ng/mL on quadrupole-time-of-flight instruments. Solvent blanks are evaporated from 50 mL lots and examined by LC-MS before a certificate of analysis is accepted; any phthalate signal above the method detection limit triggers rejection of that solvent lot for extraction use.

    Automated liquid handlers are configured with conductive polypropylene tips and a 10 mL syringe adapter, and because the density of MTBE is 0.740 g/mL at 20°C by ASTM D4052, the phase inversion after water addition is confirmed by visual inspection before upper-layer aspiration. The high vapor pressure of 27.8 kPa at 20°C means that open reservoirs lose volume by evaporation during long batch runs; reservoirs are capped and cooled to 10°C to keep evaporation below 2% per hour. In addition, the water in the solvent is limited to 0.02% by ASTM D1364 because excess water shifts the partition coefficient of lysophosphatidic acid toward the lower phase and alters relative quantitation when an internal standard is not used. Validation of lot-to-lot reproducibility in a multi-batch extraction campaign uses a pooled plasma control sample and a stable isotope-labeled internal standard mixture containing phosphatidylcholine d7 and sphingomyelin d31; the relative standard deviation of the extraction alone should be less than 15% in the absence of derivatization. If the relative standard deviation exceeds 20%, the phase boundary is re-checked and the centrifuge temperature is lowered to 4°C. The MTBE layer is diluted 1:1 with methanol containing 5 mM ammonium acetate before direct infusion for shotgun lipidomics. This extraction approach is unsuitable for matrices containing high concentrations of phospholipases unless the enzyme activity is quenched before MTBE addition, and its use for bile acid profiling requires a separate acidified extraction because the neutral pH of the MTBE-methanol-water system does not fully protonate taurine-conjugated bile acids.

    When a Solvent Must Remain Aprotic Under Reflux for 48 Hours

    When a solvent must remain aprotic under reflux for 48 hours during a lithium diisopropylamide-mediated enolate formation, methyl tert-butyl ether is selected over tetrahydrofuran because its dielectric constant of 2.6 at 25°C reduces side reactions that arise from charge separation of the enolate. The solvent is pre-dried over activated 3A molecular sieves for 72 hours until the water content measured by ASTM D1364 is below 10 mg/kg, then transferred under argon through a stainless-steel cannula into a jacketed glass reactor with a PTFE-coated thermowell. Reaction temperature is maintained at −20°C to +5°C for enolate formation and then raised to 35°C for the coupling step; heat removal from the exotherm is controlled by a circulating bath with a temperature stability of ±0.5°C over a 12-hour ramp. Because MTBE forms peroxides slowly under ambient light, the equipment train includes an in-line UV-blocking recirculation filter, and the distillation receiver is monitored with peroxide test strips calibrated at 0.5 mg/kg before solvent reuse. Batch records from pilot-plant campaigns show that residual water above 50 mg/kg causes hydrolysis of silyl-protected intermediates and reduces the isolated yield of a model steroid alkyne by up to 15 percentage points; that figure is specific to one campaign and is not a universal yield coefficient.

    Methylmagnesium bromide additions are carried out in MTBE at concentrations up to 1.0 M, with the addition rate controlled so that the internal temperature does not exceed 40°C, because the boiling point of 55.2°C provides a stable reflux under atmospheric pressure and allows solvent recovery at the end of the reaction. Solvent recovery from an aqueous quench is accomplished by redistillation at 55.2°C; the recovered distillate is re-certified for water and peroxide content before reuse because peroxides may accumulate in the still bottoms and create a thermal hazard above 10 mg/kg. For continuous-flow synthesis, MTBE is delivered by a titanium or PTFE diaphragm pump with a maximum stroke frequency of 80 rpm; the pump head is vented to a chilled condenser because the vapor pressure at the feed temperature of 30°C can cause cavitation at low suction pressure. The flash point of −28°C requires the feed vessel to be grounded and blanketed with nitrogen; the oxygen concentration in the headspace is managed below 5% by volume before the pump is started. This configuration is used for lithiation reactions because it avoids the cyclic ether autoxidation products that complicate downstream workup. This application does not tolerate the use of butylated hydroxytoluene-inhibited technical-grade MTBE because the inhibitor becomes a non-volatile residue in the final chromatographic purification step and can co-elute with the target product on silica gel using a hexane-ethyl acetate gradient. Published data for this specific configuration are limited, and each plant batch is released only after a water value below 10 mg/kg, a peroxide value below 0.5 mg/kg, and a GC purity above 99.9% by ASTM D5441 are documented.

    For the dissolution of low-molecular-weight polyisobutylene and butyl rubber prior to size-exclusion chromatography, MTBE with water below 0.02% is used as a viscosity-reducing diluent that suppresses aggregate formation occurring in pure tetrahydrofuran. The sample is dissolved at 40°C for 2 hours in a crimped glass vial with a PTFE-lined cap, at a concentration of 1.0 mg/mL, and filtered through a 0.45 µm polytetrafluoroethylene syringe filter before injection into a 7.8 mm × 300 mm styrene-divinylbenzene column set maintained at 35°C. The mobile phase is delivered at 1.0 mL/min against a backpressure of 55 bar to 70 bar, and the differential refractive index detector baseline drift is evaluated over 60 minutes after the solvent has been sparged with helium. Calibration with narrow-dispersity polystyrene standards is performed in the same solvent matrix, and the Mark-Houwink parameters for the specific elastomer are taken from the column manufacturer's technical bulletin rather than from low-molecular-weight polystyrene equivalents. This procedure is not suitable for high-molecular-weight polyolefins that require trichlorobenzene at 145°C, and its use for graft copolymers requires a solubility test before injection. Solvent lots for this application are rejected if ultraviolet absorbance at 230 nm exceeds 0.1 AU or if particulate counts above 10 µm exceed 100 particles/mL in the as-received bottle, because such contamination shortens the lifetime of the inline guard column and distorts the low-molecular-weight tail of the distribution. The high volatility of MTBE relative to tetrahydrofuran reduces the time required for fraction collection and subsequent solvent evaporation under a nitrogen stream at 35°C; however, recovery of high-boiling fractions requires a rotary evaporator with a vacuum controller set to 150 mbar to prevent sample loss due to entrainment.

    Бесплатная цитата

    Конкурентные цены высокой чистоты MTBE HPLC и электронных сортов, которые соответствуют вашему бюджету - гибкие условия и индивидуальные котировки для каждого заказа.

    Для получения образцов, цен или более подробной информации свяжитесь с нами по адресу +8618005193850 или отправить по почте sales8@ascent-chem.com.

    Мы ответим вам как можно скорее.

    Телефон: +8618005193850

    Электронная почта: sales8@ascent-chem.com

    Запрос

    Получите бесплатную сметуAscent Petrochem Holdings Co., Limited

    Гибкие условия оплаты, конкурентоспособные цены, первоклассное обслуживание — обращайтесь прямо сейчас!

    Сертификация и соответствие требованиям
    ТОП